12
Do not expose this product to high humidity(>95%
Do not let this product work below thedew pointtemperature
Table 4TheConstant Dew Point Table
AMBIENT DEW POINT
Room Temperature
(℃)
Maximum Relative humidity
20%
30%
40%
50%
60%
70%
80%
90%
95%
20
-3.5
2
6
9
12
14.5
16.5
18
19
25
0.5
6
10.5
14
16.5
19
21
23
24
30
4.6
10.5
15
18.5
21.5
24
26
28
29
35
8.5
15
19.5
23
26
28.5
31
33
34
40
13
20
24
27.5
31
33.5
36
38
39
Laser operating temperature range
2.6 Precautions for Use
a) Before supplying the power to the device, make sure that the correct voltage of the AC
power source is used (See Table 3 for the laser model and corresponding input voltage).
Failure to connect power source correctly will damage the device;
b) Failure to follow the instructions may cause malfunction and damage to the device,
such damage is not covered by warranty.
c) It is very important to ensure the cleanness of the calibrated laser output head,
otherwise it will cause irreparable damage to the laser.
d) Please inspect the output head carefully for dust or other contamination. Use
appropriate lens paper to clean it if necessary. Do not touch the output lens at any time;
as well as remember to cap the output head when it is not in use, and make sure the cap
is clean;
e) Failure to follow the specified instructions may result in the loss of laser power, and
such loss will not be covered by the warranty.

Questions and Answers: