4.5 Steps of Installation
a) Carefully takeout the laser from the box and move it to the installing position and then
lock the casters;
b) Remove the output cable protective cap and check the output lens for dust with strong
light and clean it if necessary, then cover the output cable protective cap;
c) Install the output cable on the processing equipment according to the actual situation
(install the output head cooling water pipe at the same time), pay attention to the output
cable and head,then remove the protective cap andconfirm that the output lens is clean
and install the output head
;
d) Connect cooling water pipe;
e) Connect the control line and power according to the control mode.
4.6 Steps of Starting
It is determined that the air switch is disconnected, and all electrical connections must be
completed before the laser is powered on;
a) Make sure that the pins the 24-pin are closed;
b) Turn on the chiller and check leakage. If there is no water leakage, turn off the chiller
and wait for the laser to turn on;
c) Turn on the air switch ;
4.7 Functions of the clientware
The RFL-C3000S-CE clientware communicates with the main control board through UDP
when it is working. Through the background program running in the software and the
human-computer interaction operation, the laser parameters are read and set and the control
functions are realized. The interface displayed by the software is divided according to functional
categories, including control, alarm, about, language selection, authorization, working mode
selection and other pages.