Before approaching the system again, wait for at least 30 min until the reaction has abated.
Wear proper protective clothing (respiratory protection, protective goggles, protective suit, rubber or
plastic gloves).
Provide ventilation.
When approaching the system again, pay attention to odors.
Remove all lens fragments.
Avoid raising or dispersing dust.
Disposal
The ZnSe dust and the lens are to be collected drily and disposed of with fragments, broom,
shovel and protective clothing into hermetically sealable containers or plastics bags as
hazardous waste.
Do not dispose of optical components as domestic waste, and do not let them enter the
sewer or water bodies.
Dispose of according to regulations and laws valid in the users' country.
2.9 In case of emergency
What to do in the event of malfunctions
In unusual operating conditions, open the lid to stop the machining process or, if available, press the
emergency stop button and switch off the machine.
If necessary, disconnect the machine from the main power supply.
Inform the laser protection officer and your supervisor.
Follow the instructions.
Repair work must only be carried out by Trotec Laser GmbH service technicians.
In the event of a fire: Fight the fire with a CO
2
fire extinguisher as far as is possible without risk.
Notice
After a deletion, Trotec Technical Support must be involved before the system is put back into
operation.
What to do in the event of an accident, first aid
If eye damage occurs due to laser radiation (if the MPD values are exceeded), the casualty must present
to an ophthalmologist immediately.
The assumption of eye damage is justified if radiation with laser beams has been used and the MPD
values have been exceeded.
First aiders must protect themselves.
Switch off the machine.
Rescue the injured person from the danger area and provide first aid.
Call an emergency doctor!