15.21Transducerset-upmenuoptions
TheTransducerSet-upmenushouldbeusedwhensettingupyourmultifunctiondisplayforthersttimeorwheninstallingadepth
transducer.
MenuItemDescriptionOptions
Transducer
Selecttheappropriatetransducertypefromthosedisplayed.
Sometransducermaybedetectedbythesystemautomatically.
Optionsavailablearedependantonthesonarmodule
connected.
SpeedTransducerSelecttheappropriatespeedtransducerfromthoseavailable.
Thisoptionisonlyavailableifyouarenotusingacombined
Depth/SpeedorDepth/Speed/Temperaturetransducer.
Optionsavailablearedependantonthesonarmodule
connected.
DepthOffset(waterline)Offsetrepresentsthedepthofthetransducer(relativetothe
waterline).
–9.9to+9.9feetorequivalentunits
SpeedOffsetOffsetappliedtothespeedlog.0to100%
TemperatureOffsetOffsetappliedtothetemperaturetransducervalue.–9.9to+9.9°Forequivalentunits
FishnderTransducerCalibration
Yourshndertransducermustbecalibratedcorrectlytoachieve
accuratedepthreadings.
Themultifunctiondisplayreceivestheimagefromasonarmodule
whichprocessessonarsignalsfromatransducermountedinthe
water.Ifthetransducerisequippedwithaspeedpaddlewheeland
temperature-sensingthermistor,thesonarmodulecalculatesspeed
andtemperature.T oensureaccuratereadings,itmaybenecessary
tocalibratethetransducer(s)byapplyingoffsetstodepth,speed
andtemperature.Asthesesettingsareheldinthesonarmodule
andrelatetothetransducer,theyareappliedsystem-wide.
DepthOffset
Depthsaremeasuredfromthetransducertotheseabed,butyou
canapplyanoffsetvaluetothedepthdata,sothatthedisplayed
depthreadingrepresentsthedepthtotheseabedfromeitherthe
keelorthewaterline.
Beforeattemptingtosetawaterlineorkeeloffset,ndoutthe
verticalseparationbetweenthetransducerandeitherthewaterline
orthebottomofthekeelonyourvessel,asappropriate.Thenset
theappropriatedepthoffsetvalue.
D9343--2
1 2 3
1
Waterlineoffset
2
Transducer/Zerooffset
3
Keeloffset
Ifanoffsetisnotapplied,displayeddepthreadingsrepresentthe
distancefromthetransducertotheseabed.
Settingthedepthoffset
Fromtheshnderapplication:
1.SelectMenu.
2.SelectSet-up.
3.SelectTransducerSet-up.
4.SelectDepthOffset.
Thedepthoffsetnumericadjustcontrolisdisplayed.
5.Adjusttheoffsettotherequiredvalue.
6.SelectOktoconrmsettingandclosethenumericadjustcontrol.
Settingthespeedoffset
Fromtheshnderapplication:
1.SelectMenu.
2.SelectSet-up.
3.SelectTransducerSet-up.
4.SelectSpeedOffset.
Thespeedoffsetnumericadjustcontrolisdisplayed.
5.Adjusttheoffsettotherequiredvalue.
6.SelectOktoconrmsettingandclosethenumericadjustcontrol.
SettingtheTemperatureoffset
1.SelectMenu.
2.SelectSet-up.
3.SelectTransducerSet-up.
4.SelectTemperatureOffset.
Thetemperatureoffsetnumericadjustcontrolisdisplayed.
5.Adjusttheoffsettotherequiredvalue.
6.SelectOktoconrmsettingandclosethenumericadjustcontrol.