Raymarine AXIOM 2 XL - Grounding - Optional Grounding Point

Raymarine AXIOM 2 XL
108 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Groundingoptionalgroundingpoint
Frequenciesemittedfromequipmentsuchasswitchmodepowersupplies
orMF/HFtransmittersetc.cancauseinterferencewithyourdisplay’
s
touchscreen.Ifyouexperienceissueswithtouchscreenperformance,fitting
anadditionaldedicatedgroundconnectioncanresolvetheissue.
Important:
ThegroundpointshouldONL
Ybeconnectedwhentouchscreen
interferenceisobserved.
Useasmallflatbladescrewdrivertoremovethecoveroverthegrounding
screwhole .
Connectoneendofthegroundwire(notsupplied)toyourdisplayusingthe
suppliedcrimp,washerandscrew.
Connecttheotherendofthegroundwiretoeitherthevessel'sRFground
point,oronvesselswithoutanRFgroundsystem,thenegativebattery
terminal.
Thedcpowersystemshouldbeeither:
Negativegrounded,withthenegativebatteryterminalconnectedtothe
vessel'sground;or
Floating,withneitherbatteryterminalconnectedtothevessel'sground.
Ifseveralitemsrequiregrounding,theymayfirstbeconnectedtoasingle
localpoint(e.g.withinaswitchpanel),withthispointconnectedviaasingle,
appropriately-ratedconductor,tothevessel’scommonRFgroundpoint.
Implementation
Thepreferredminimumrequirementforthepathtogroundisviaaflattinned
copperbraid,witha30Arating(1/4inch)orgreater.Ifthisisnotpossible,an
equivalentstrandedwireconductormaybeused,ratedasfollows:
forrunsof<1m(3ft),use6mm
2
(#10AWG)orgreater.
forrunsof>1m(3ft),use8mm
2
(#8AWG)orgreater.
Inanygroundingsystem,alwayskeepthelengthofconnectingbraidor
wiresasshortaspossible.
References
ISO10133/13297
BMEAcodeofpractice