Type2:
Type3:
Hydraulicpump
Locationandmountingrequirements:
•MUSTbemountedonasolidstructuretoavoidvibrationthat
coulddamagethehydraulicpipes.
•MUSTbemountedonadryhorizontalsurface,clearofspray
waterandpossibleimmersion.
•Excessivetemperature,vibrationandfumesintheatmosphere
candrasticallyreducemotorbrushlife.
•MUSTbemountedleveltoorabovethehydraulicram,toprevent
airfromcollectingintheram.
•MUSTbeaccessibleforfutureservicing.
Reservoir
Locationandmountingrequirements:
•MUSTbemountedvertically,ideallytoabulkhead.
•MUSTbemountedatleast150mm(6in)ABOVEthehydraulic
pumpandhydraulicram,toensureagoodsupplyofuidtothe
system.
•MUSTbeaccessibleforhydraulicuidtop-upsandrells.
•RaymarinerecommendstheuseofM8boltsandsuitablenuts
andwasherstosecurethereservoirtothevessel.
Pipes
ThepipestransportuidandpressurearoundtheHydraulicLinear
Drivesystem.Thesystemissuppliedpre-plumbed,pre-lled,and
pre-bled,withjustthereservoirempty.Howeveryoumustobserve
thefollowingwhenhandlingandpositioningthepipes:
•DoNOTallowacutebendsinthepipes.Theminimumbend
radiusforthepipesis7.6cm(3in).
•PipesmustNOTtouchanypartofthevessel.
•Ensuretherearenokinksinthepipes.
•Ensurepipesarenotcutorchaffed.
Planning
17