Note:Forcompleteconnectionandinstallationinstructionsfor
thecoursecomputerrefertothedocumentationthataccompanies
theunit.
Cableextensions
YoumayneedtoextendtheHydraulicLinearDrivecables.
Clutchcable(fromhydraulicramtocoursecomputerclutch
connection)useminimum1.5mm
2
(16AWG)coppercable.
Motorcable(fromHydraulicpumptocoursecomputermotor
connection)usethefollowingtabletodeterminethecorrect
cablegaugerequired:
DrivetypeCablelength
Cablegauge
(AWG)
Cablegauge
(mm
2
)
Type2(12V)Upto5m(16ft)
106
Upto7m(23ft)
810
Upto16m(52ft)
616
Type2(24V)Upto3m(10ft)
124
Upto5m(16ft)
106
Upto10m(32ft)
810
Upto16m(52ft)
616
Type3(12V)Upto5m(16ft)
810
Upto7m(23ft)
616
Upto16m(52ft)
425
Type3(24V)Upto5m(16ft)
106
Upto7m(23ft)
810
Upto16m(52ft)
616
Usesuitableelectricalconnectorsorjunctionboxestoconnectthe
HydraulicLinearDrivecablestothecableextensions.
Note:DoNOTuntwistthepumpcablesorremovethe
suppressionferrite.