LEDindications
Thisproductcontains2diagnosticLEDs,onefortheSeaT alk
ng
connectionandonefortheengineCANbus
connection.TheLEDsforthisproductash(blink)insetsequenceswhichprovidesinformationonthe
currentstatusoftheunitfordiagnosticsandtroubleshootingpurposes.
LEDcolorSeaTalk
ng
LEDcode
EngineCANbusLED
codeStateUseraction
Red
Poweringup
None(normalpoweruptakes
approximately6seconds.)
Green
15s
15s
NormaloperationNone
Green
15s
DeviceNetpowered
on,SeaTalk
ng
poweredoff
PowerupSeaTalk
ng
network.
Red
9s
9s
Networkconnected
butnotrafc(no
messagereceivedin
morethan5seconds.
Red
SeaTalk
ng
powered
on,DeviceNetOff.
Red
3s
3s
Generalerror(Device
connectedwrongway
round
SwapoverSeaTalk
ng
andDeviceNet
connections
Red
Softwaredownloadin
progress(longerthan
6seconds.)
Waitfordownloadtocomplete
Multifunctiondisplaywillindicate
whensoftwaredownloadis
completed.
Note:IfanyotherLEDsequenceotherthandescribedaboveisseenandpersistspleasecontact
Raymarinetechnicalsupport.
ResettingtheECI-100
AspecialisttoolisrequiredtoresettheECI-100,
contactRaymarineProductSupportforfurther
information.
YourECI-100willneedresettingifithaspreviously
beenusedonadifferentenginetype.