ThetextSTART2alternatingwiththenewcalibrationfactoris
displayedatthetopofthepage.
Thedisplayeddistancefreezes
D12468-1
Spe e d
Note:Thedisplayeddistanceshouldbeveryclosetotheactual
(measured)distanceofthecalibrationrun.
9.Ifyouaresatisedwiththeresultsoftherstcalibrationrun,
presstheDepthandSpeedbuttonssimultaneouslytosavethe
newcalibrationfactor,exitspeedcalibrationandreturntothe
statuspage.
10.Ifyouwanttocarryoutasecondcalibrationrun,pressthe
Speedbutton.
11.Followsteps5to7aboveagaintocompleteasecondcalibration
run.
12.AttheendofthereturnlegpresstheSpeedbutton
Atthispoint:
ThetextENDalternatingwiththenewcalibrationfactoris
displayedatthetopofthepage.
Thedisplayeddistancefreezes.
D12469-1
Spe e d
13.Toexitthespeedcalibrationrunatanytime,pressandholdthe
DepthandSpeedbuttonssimultaneouslyfor4seconds.
Dealercalibration
Thedealercalibrationproceduresinclude:
i50Depthi50Speedi50Tridata
SettingUsercalibration
optionsonoroff.
SettingUsercalibration
optionsonoroff.
SettingUsercalibration
optionsonoroff.
Settingrequireddepth
response.
Settingrequiredspeed
response.
Settingdatasourcefor
speedinformation.
Settingboatshowmode
onoroff.
SettingrequiredVMG
response.
Settingrequiredspeed
response.
RestorefactorydefaultSettingboatshowmode
onoroff.
Settingrequireddepth
response.
RestorefactorydefaultSettingboatshowmode
onoroff.
Restorefactorydefault
Settingdealercalibrationoptionsi50Depth
Duringnormaloperation:
1.PressandholdtheDepthandAlarmbuttonssimultaneously
forapproximately14secondstodisplaythedealercalibration
entrypage.
Depth
+
Ala rm
D12 4 7 0-1
10
15
20
25
30
35
40
45
50
55
60
5
14
2.PresstheOffsetandResetbuttonssimultaneouslytodisplay
theusercalibrationaccesspage.
+
D12 4 7 0-1
Re s e tOffse t
3.UsetheOffsetorResetbuttonstoswitchtheusercalibration
onandoff.
4.PresstheDepthbuttontodisplaythedepthresponsepage.
D12 4 7 2-1
De pth
5.UsetheOffsetorResetbuttonstosettherequireddepth
responsesetting.
6.PresstheDepthbuttontodisplaytheboatshowmodepage.
D12 4 7 3-1
De pth
7.PresstheDepthbuttontodisplaythefactoryresetpage.
D12 4 7 4-1
De pth
8.UsetheOffsetorResetbuttonstoresettheunitssettingsto
factorydefaultvalues.
9.T oexitthedealercalibrationpagesatanytime,pressandhold
theDepthandAlarmbuttonssimultaneouslyforapproximately
2seconds.
Settingdealercalibrationoptions-i50Speed
Duringnormaloperation:
1.PressandholdtheSpeedandTripbuttonssimultaneously
forapproximately14secondstodisplaythedealercalibration
entrypage.
Spe e d
+
Trip
D12 4 7 5-1
10
15
20
25
30
35
40
45
50
55
60
5
14
2.PresstheTimerandResetbuttonssimultaneouslytodisplay
theusercalibrationaccesspage.
+
D12 4 7 6-1
Re s e tTim e r
3.PresstheSpeedbuttontodisplaythespeedresponsepage.
D12 4 7 7-1
Spe e d
4.UsetheTimerorResetbuttonstosettherequiredspeed
responsevalue.
5.PresstheSpeedbuttontodisplaythespeedVMGresponse
page.
D12 4 7 8-1
Spe e d
6.UsetheTimerorResetbuttonstosettherequiredVMG
responsevalue.
7.PresstheSpeedbuttontodisplaytheboatshowmodepage.
D12 4 7 9-1
Spe e d
8.UsetheTimerorResetbuttonstoswitchboatshowmodeon
andoff.
9.PresstheSpeedbuttontodisplaythefactoryresetpage.
D12 4 8 0-1
Spe e d
10.UsetheTimerorResetbuttonstoresettheunitssettingsto
factorydefaultvalues
11.T oexitthedealercalibrationpagesatanytime,pressandhold
theSpeedandTripbuttonssimultaneouslyforapproximately
2seconds.