Note:Connectors1and2arerotavectaconnections,
connectors3to7areforwindtransducers.
Makingtransducerconnections
Althoughthetransducercableisttedwithspadeconnectorsfor
directconnectiontotherearoftheunit,itmaybenecessaryto
removethesetofacilitateinstallation,e.g.ifthecablehastobe
routedthroughnarrowapertures.1/8thspadeterminalswillbe
required(notsupplied),toreplacethoseremoved.Whentting
thenewspadeconnectors,preparethecablesasdetailedbelow:
3 mm
6 mm
50 mm
1
2
D12 35 9-1
1.Preparethecableasshownin1above.
2.Foldbackthewirestrandsandinsertintothenewspade
connectorasshownin2above.
3.Ensurethewirestrandsdonotextendbeyondtherearofthe
spadeconnectorinsulation.
4.Crimptheconnectortothewire.
iTC-5connection
TransducerscanbeconnectedtoaSeaT alk
ng
networkusing
Raymarine'sInstrumenttransducerconverter(iTC-5)andani70
instrument,thedatacanthenberepeatedonani50/i60unit.
12 V
D12 03 3-3
1 2 3 4
5
6 7 8
1
i50Depth(Repeater)
2
i70Instrument(Master)
3
i50Speed(Repeater)
4
i60Wind(Repeater)
5
iTC-5
6Depthtransducer
7
Windvanetransducer
8
Speedtransducer
Note:TransducersconnectedtotheiTC-5mustbecalibrated
usingani70(master)unit.Transducersconnectedtothe
iTC-5cannotbecalibratedusingani50/i60.
MakingiTC-5transducerconnections
ForinstructionsonconnectingtransducerstoyouriTC-5refer
totheiTC-5handbook.
Powerconnection
PowerissuppliedtotheproductovertheSeaT alk
ng
network.
ASeaTalk
ng
systemrequiresone12Vdcsupply,connectedto
theSeaTalk
ng
backbone.Thiscanbeprovided:
Byabatteryviathedistributionpanel,or
FromaRaymarinecoursecomputer,viaaSeaT alkora
SeaTalk
ng
system.
Powerconnectionexample
SeaTalk
ng
powerconnection
SeaTalk
ng
D12 39 1-1
12 V
3
1
2
1
SeaTalk
ng
instrument.
2
SeaTalk
ng
instrument.
312Vdcvesselpowersupply.
Warning:Groundingnotrequired
ThisproductisfullyinsulatedanddoesNOT
requireseparategrounding.
Warning:Positivegroundsystems
Donotconnectthisunittoasystemwhichhas
positivegrounding.
SeaTalkpowerprotection
Thepowersupplymustbeprotectedbya5Afuseoracircuit
breakerprovidingequivalentprotection.
Raymarinerecommendsthatthepowerisconnectedtoa
SeaTalksysteminsuchawaythatthecurrentdrawnoneach
sideofthepowerconnectionpointisequal.
SeaTalkpowercables
PartnumberDescription
D229
SeaTalkpowercable.
SeaTalk
ng
powerprotection
Thepowersupplymustbeprotectedbya5Afuseoracircuit
breakerprovidingequivalentprotection.
Raymarinerecommendsthatthepowerisconnectedtoa
SeaTalk
ng
systeminsuchawaythatthecurrentdrawnoneach
sideofthepowerconnectionpointisequal.
SeaTalk
ng
powercables
PartnumberDescription
A06049
SeaTalk
ng
powercable