Alarm name Alarm type Description Action
Pilot start up Alarm Will display
start up for
20 seconds
everytime
the pilot is
powered up
Self
cancelling.
Waypoint
advance
Alarm Indicates
change in
waypoint
name or ID
and direction
to turn to new
waypoint.
Initiated in
Track mode.
Change
pilot
mode.
Accept
new
waypoint
route.
No Wind
data
Alarm
SmartPilot is
in Wind Vane
Mode but has
not received
Wind Angle
data for 30
seconds.
Check
wind data
source
and con-
nections.
Pilot drops
out of
wind vane
mode and
reverts
to auto
mode.
Change
pilot mode
No speed
data
Alarm
Speed data
has stopped .
Check
Seatalk
connec-
tions for
short or
open cir-
cuit.
Check
system for
Seatalk
device
fault.
SeaTalk 1
fail
Alarm
SeaTalk
channel 1
has a com-
munication
problem.
Change
pilot
mode.
SeaTalk 2
fail
Alarm
SeaTalk
channel 2
has a com-
munication
problem.
Change
pilot
mode.
Drive short Warning Indicates a
short circuit
in the drive
unit
Pilot will
power
down
User to
x short
circuit
Alarm name Alarm type Description Action
Clutch short
Warning Indicates a
short circuit
in the Clutch
Check
clutch con-
nections at
SPX and
drive unit
. Check
drive unit
clutch.
User to
x short
circuit
Solenoid
short
Warning Indicates a
short circuit in
the solenoid
Pilot will
power
down
User to
x short
circuit