UNC100 Hardware Manual V1.4 RBH Access Technologies Inc.
Page 21 of 36
NURC2000 may also be used in place of RC-2 panels.
The D-NET connects IOC-16, RC-2, SafeSuite™ panels, PC-100, NRC2000, and NURC2000 devices in a
daisy chain fashion (parallel connection) to the network controller. Device controllers do not have to be
addressed sequentially. However, using sequential device controller addressing is recommended as this
makes your cabling diagrams easier to follow and simplifies troubleshooting as the devices are in the correct
numerical sequence.
UNC100 D-NETs comprising SafeSuite™ panels, PC-100, NIRC2000, and NURC2000 devices must have
the last unit in the line terminated.
Device Controller Address Assignment
* The first NURC is on the UNC100 – Therefore, the first physical RC2 to be connected will start at
address 2.