10 | P a g e
SETUP WITH EXTERNAL WALL MOUNTED FAN TERMINAL
Wall mounted fan module
terminal must be installed with clearances as
specified by AS/NZS 5601.1 Clause 6.9.3
Run exhaust flue and air intake flue as required
Maximum run 5mts. Flues can be run next to each
other. Maintain the required clearances to
combustibles.
Connection to appliance
Cut tube to length where required.
Ensure ends are burr free and round, test fit flue will
slide over connection.