45 | P a g e
AERATION ADJUSTMENTS and BURNER SIZES
1. The primary air is entrained through the aeration cap located at the end of the burner. The aeration cap is
factory preset to Natural Gas Driftwood media. Note for LPG conversion the burner will change - refer
table below
MODEL
NAT GAS
LPG
800
26.5 diameter open area
26.5 diameter open area
Inspire 700 Driftwood
22.0
22
Inspire 700 Pebbles
20.0
NA
Inspire 900 Driftwood
16.0
20.0
Inspire 900 Pebbles
12.0
NA
Inspire 1100 Driftwood
22.0
26.0
Inspire 1100 Pebbles
16.0
NA
2. Fan restrictor (mounted in outlet tube of power flue fan) 31.8mm diameter
3. Burner sizes - models for appliance
Inspire 700 Nat Gas
Inspire 700 LPG
BEKEART Furigas- 0346
440mm long
50mm diameter
Inspire 900 Nat Gas
KEEGAS BURNER
BE- SS555-527WF-N5
555mm long
50mm diameter
Inspire 900 LPG
Inspire 1100 LPG
BEKAERT- 1647
555mm long
50mm diameter
Inspire 1100 Nat Gas
KEEGAS burner
BE-SS800-770WF-N5
800mm long
50mm diameter