36 | P a g e
COMMISSIONING PROCEDURE
Once the fire is installed.
• Install media.
• Connect to gas and power.
• Fit firebox door.
• Check for gas leaks.
• Connect powerflue module loom to fan control unit.
• Carry out the lighting procedure.
• Check burner pressures and inlet supply pressure (Valve is non-adjustable).
• Check appliance for combustion (CO) leakage.
• Turn off
• Fit trim.
• Handover instructions to owner.
• Instruct owner on how to operate the fireplace safely.
• Instruct owner how to isolate the appliance in an emergency.
OPERATION USER INSTRUCTIONS
Do not operate if you smell gas. Turn appliance off, extinguish any open flame.
Contact your installer or a licensed gasfitter.
Do not use if any part of this appliance has been submerged in water. Contact your installer or a qualified
service technician.
Solid fuels must not be burnt in the fire. Leaves, sticks, wood, paper food or material must be kept away
from the fire.
Appliance operates with luminous flames; carbon deposits may occur during operation.
Should the appliance fail to ignite or was recently turned off, allow 2 minutes before attempting to reignite
appliance.
In the event of abnormal operation please contact your licensed gas installer, gas service personnel or Real
Flame Pty Ltd. Abnormal operation may consist of the following, noisy fan, excessive or small flame, unusual
flame appearance or colour, excessive sooting or other.
APPLIANCE QUICK OPERATION
1. Press power button on the remote.
2. Press Temperature button until ON is displayed.
3. Set the desired temperature - it must be above the room temperature for the appliance to operate.
4. Appliance will start once the flame symbol appears on the remote.
5. Appliance will perform a 60 seconds pre-purge, then sparking will occur.
NOTE: Appliance takes up to 60 sec to pre-purge prior to sparking.