EasyManua.ls Logo

Real Flame 700 - APPLIANCE DATA AND DIMENSIONS; Model Specifications; Inlet Pressure & Cut-out Dimensions

Real Flame 700
51 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
4 | P a g e
DATA PLATE (Affixed to the base of the unit for reference to gas pressure & consumption)
Inspire 700
GAS TYPE
INJECTOR SIZE
TPP
N.G.C. (MJ/hr)
Natural Gas
1 X 2.30mm
0.88kPa High
0.40kPaLow
22.0 High/16.0 Low
LPG
1 X 1.35mm
2.48kPa High
1.58kPaLow
22.0 High/17.0 Low
Inspire 900
GAS TYPE
INJECTOR SIZE
TPP
N.G.C. (MJ/hr)
Natural Gas
1 X 2.45mm
0.89kPa high
0.42kPa Low
24.0 High/16.0 Low
LPG
1 X 1.45mm
2.49kPa High
1.58kPaLow
24.0 High/19.0 Low
Inspire 1100
GAS TYPE
INJECTOR SIZE
TPP
N.G.C. (MJ/hr)
Natural Gas
1 X 2.65mm
0.88kPa High
0.41kPaLow
29.0 High/20.0 Low
LPG
1 X 1.50mm
2.45kPa High
1.51kPaLow
27.0 High/21.0 Low
Max - Min inlet pressure range
Natural gas: 1.13kPa - 5.00 kPa
LPG: 2.75kPa - 5.00 kPa
Note: Gas pressures are not adjustable on the Inspire models.