Drawing No. LP0932 Released 2018-01-12



1-IN 
DISPLAY PARAMETER
FACTORY
SETTING
USER SETTING
YP Input Type -J
CAL Temperature Scale F
dCP Decimal Resolution 0.0
FLr Digital Filtering
bANd Input Filter Band 1.0
F Shift/Offset 0.0
dP1 Display Value Scaling Point 1 0
dP2 Display Value Scaling Point 2 1000
PLO Setpoint Low Limit -14.0
PI Setpoint High Limit 2192
RMP Remote Input Type 4-20
rP1 Remote Input Low Display 0.0
rP2 Remote Input High Display 100.0
Rio Remote Setpoint Ratio Multiplier 1.000
biA Remote Setpoint Bias 0.0
CJC Cold Juction Compensation On
r1 User1 Function NON
r2 User2 Function NON
F1In F1 Key Function NON
F2In F2 Key Function NON
2-OP
DISPLAY PARAMETER
FACTORY
SETTING
USER SETTING
OPAC Control Action r1r2
CRL Auto Control Mode PId
P Setpoint Mode P
CYC1 OP1 Cycle Time 2.0
OP1L OP 1 Power Low Limit 0.0
OP1 OP 1 Power High Limit 100.0
IF01 Input Fail OP1 Power Level 0.0
An1L Analog Low 0.0
An1 Analog High 100.0
CYC2 OP2 Cycle Time 2.0
OP2L OP 2 Power Low Limit 0.0
OP2 OP 2 Power High Limit 100.0
IF02 Input Fail OP2 Power Level 0.0
gAN2 Relative Gain 1.00
db-2 Deadband/Overlap 2.0
CY On/Off Control Hysteresis 2.0
3-LC
DISPLAY PARAMETER
FACTORY
SETTING
USER SETTING
P Setpoint dIP
C1 Current Transformer dIP
OP1 Output 1 Power PArA
OP2 Output 2 Power PArA
PrP Setpoint Ramp Rate PArA
PId PID Group PArA
r- Controller Status dIP
P Profile Status PArA
r-i Profile Segment Time Remaining PArA
ProF Setpoint Profile PArA
Pg Starting Profile Segment LOC
DISPLAY PARAMETER
FACTORY
SETTING
USER SETTING
PInd Profile Indicator dIP
OPOF Output Power Offset PArA
ProP Proportional Band PArA
In Integral Time PArA
dR Derivative Time PArA
dIn Integration Default LOC
AL-1 Alarm 1 Value PArA
AL-2 Alarm 2 Value PArA
AL-3 Alarm 3 Value PArA
ALr Alarm Reset PArA
PL Setpoint Select PArA
N Auto-Tune Code Id
CrL Auto Control Mode Id
P Setpoint Control Mode LOC
rnF Control Mode Transfer Id
dV Deviation Value dIP
P1 Setpoint 1 dIP
P2 Setpoint 2 dIP
Cod Access Code 0
4-AL
DISPLAY PARAMETER
FACTORY
SETTING
USER SETTING
AC1 Alarm 1 Action NON
Li1 Alarm 1 Annunciator nor
r1 Alarm 1 Reset Mode Auo
b1 Alarm 1 Standby NO
AL-1 Alarm 1 Value 100
IFA1 Alarm 1 Input Fail Action OFF
AC2 Alarm 2 Action NON
Li2 Alarm 2 Annunciator nor
r2 Alarm 2 Reset Mode Auo
b2 Alarm 2 Standby NO
AL-2 Alarm 2 Value 200
IFA2 Alarm 2 Input Fail Action OFF
AC3 Alarm 3 Action NON
Li3 Alarm 3 Annunciator nor
r3 Alarm 3 Reset Auo
b3 Alarm 3 Standby NO
AL-3 Alarm 3 Value 300
IFA3 Alarm 3 Input Fail Action OFF
AY Alarm Hysteresis 1
Colr Change Display Color OFF
-C
DISPLAY PARAMETER
FACTORY
SETTING
USER SETTING
YP Communications Type r
bAd Baud Rate 3k4
dAA Data Bit
PArb Parity Bit NO
Addr Unit Address 24