Mosaic fieldbus modules
8540467 • 04/10/2018 • Rev.0 12
The "Diagnostic code" field
"Diagnostic code"
Both contacts have not returned to their rest position
Simultaneous control failed
The two contacts of a generic two-channel input do not close
simultaneously
Two hands Simultaneity failed hand 1
Incorrect connection of one side of a two-hand command
Two hands Simultaneity failed hand 2
Incorrect connection of one side of a two-hand command
The selector cannot have more than one active input
The selector cannot have any active input
Presence of diagnostics on an OUT_TEST connected to the input
Redundancy check failed on entry
Output connected to other inputs
The test output is not connected to the configured input
Output OK but input connected to 24DC
Short circuit between photocell test and
photocell input
The response time of the photocell is too low
Photocell does not respond
Test signal on the emitter is not present on the photocell receiver
Short circuit between photocells
Test signal is present on two different photocells
Safety carpet not connected
One of the two carpet connections is not correct
Output not congruent to feedback
Test signal applied to the input is present on more than one OUT_TEST
Test signal is present on more than one input
Test signal applied to the input is not present on the OUT_TEST
Redundancy check failed on OUT_TEST
MVx Proxy resource missing
MVx Encoder resource missing
MVx Resource proxy encoder missing
MVx Resource proxy1 proxy2 missing
MVx Resource encoder1 encoder2 missing
MVx Frequency congruence error
MVx Encoder supply missing
MA4C Reading out of lower threshold
MA4C Reading out of upper threshold
MA4C Mismatch between channels
Simultaneity two failed hands
The two contacts of a two-handed control do not close at the same time
Input with failed test at startup
Reset to an input with manual reset has not been activated
TWO-HAND concurrent failed
Two-hands switch has to change state simultaneously
The input has manual reset and has not been restarted
Table 4