Mosaic fieldbus modules Addendum1
26/09/2018 V1.0 20/32
EtherNet/IP (MBEI)
Process data mapping (Class 1 Connection)
Assembly instance 96h (Connection point T->O Consuming Instance)
Byte offset
Size
Name
0
USINT
Fieldbus input byte 0
1
USINT
Fieldbus input byte 1
2
USINT
Fieldbus input byte 2
3
USINT
Fieldbus input byte 3
T->O connection type: Point-to-point, Multicast
Assembly instance 64h (Connection point O->T Producing Instance)
Byte
offset
Size
Name
0
USINT
System status
1
USINT
Reserved
2
USINT
Input status byte 0
3
USINT
Input status byte 1
4
USINT
Input status byte 2
5
USINT
Input status byte 3
6
USINT
Input status byte 4
7
USINT
Input status byte 5
8
USINT
Input status byte 6
9
USINT
Input status byte 7
10
USINT
Input status byte 8
11
USINT
Input status byte 9
12
USINT
Input status byte 10
13
USINT
Input status byte 11
14
USINT
Input status byte 12
15
USINT
Input status byte 13
16
USINT
Input status byte 14
17
USINT
Input status byte 15
18
USINT
Fieldbus input byte 0 feedback
19
USINT
Fieldbus input byte 1 feedback
20
USINT
Fieldbus input byte 2 feedback
21
USINT
Fieldbus input byte 3 feedback
22
USINT
Probe status byte 0
23
USINT
Probe status byte 1
24
USINT
Probe status byte 2
25
USINT
Probe status byte 3
26
USINT
OSSD status byte 0
27
USINT
OSSD status byte 1
28
USINT
OSSD status byte 2
29
USINT
OSSD status byte 3
30
REAL
Analog data float 0
34
REAL
Analog data float 1
38
REAL
Analog data float 2
42
REAL
Analog data float 3
46
REAL
Analog data float 4
50
REAL
Analog data float 5
54
REAL
Analog data float 6
58
REAL
Analog data float 7
62
REAL
Analog data float 8
66
REAL
Analog data float 9
70
REAL
Analog data float 10
74
REAL
Analog data float 11
78
REAL
Analog data float 12
82
REAL
Analog data float 13
86
REAL
Analog data float 14
90
REAL
Analog data float 15
O->T connection type: Point-to-point Supported trigger types: Cyclic, COS
Assembly instance 05h (Configuration Data)
Set this instance to size 0