Why is my REMEHA Boiler Waiting For Configuration Number?
- XxharrisSep 14, 2025
If your REMEHA Boiler is Waiting For Configuration Number, it indicates a configuration error or unknown configuration number. To resolve this, reset CN1 and CN2.
Why is my REMEHA Boiler Waiting For Configuration Number?
If your REMEHA Boiler is Waiting For Configuration Number, it indicates a configuration error or unknown configuration number. To resolve this, reset CN1 and CN2.
What does Configuration Error mean on my REMEHA Quinta Ace 160 Boiler?
If a Configuration Error occurs on your REMEHA Boiler, it indicates a configuration error or unknown configuration number. To resolve this, reset CN1 and CN2.
What causes the Gas Valve Control internal blocking in my REMEHA Boiler?
If Gas Valve Control internal blocking occurred in your REMEHA Boiler, it could be due to: * Security kernel error: Restart the boiler. * CU-GH PCB issue: Replace the CU-GH PCB.
Why is the ionization current below the limit in my REMEHA Boiler?
If the measured ionization current is below the limit in your REMEHA Boiler, it could be due to several reasons: * No flame during operation: Vent the gas supply to remove air. * Gas valve issues: Ensure the gas valve is fully opened and check the gas supply pressure. * Air supply or flue gas blockage: Verify that the air supply inlet and flue gas outlet are not blocked. * Flue gas recirculation: Ensure there is no recirculation of flue gases.
Why has the flow temperature exceeded the maximum operating value in my REMEHA Quinta Ace 160 Boiler?
If the flow temperature has exceeded the maximum operating value in your REMEHA Boiler, it could be due to: * A flow temperature sensor above normal range (high-limit thermostat): Check the wiring and connectors for bad connections. * No flow or insufficient flow: Check the circulation (direction, pump, valves), water pressure, and the cleanliness of the heat exchanger.
Why does my REMEHA Quinta Ace 160 have 5 unsuccessful burner starts?
If the REMEHA Boiler detects 5 unsuccessful burner starts, it could be due to: * No ignition spark: Check the wiring between the CU-GH PCB and the ignition transformer. * Ionisation/ignition electrode issues: Check for breakdown to earth. * Burner cover condition: Check the condition of the burner cover and the earthing SU PCB; replace the SU PCB if faulty. * Ignition spark but no flame: Vent the gas pipes to remove air.
What causes the flue gas temperature to exceed the maximum operating value in a REMEHA Quinta Ace 160?
If the flue gas temperature has exceeded the maximum operating value in your REMEHA Boiler, it could be due to: * Maximum flue gas temperature exceeded: Check the flue gas outlet system. * Heat exchanger issues or faulty sensor: Check the heat exchanger to ensure that the flue gas side is not clogged and replace the sensor if it's faulty.
What does it mean when my REMEHA Quinta Ace 160 displays a Communication Error?
If a Communication Error occurs in your REMEHA Boiler, it could be due to: * Communication error with the security kernel: Restart the boiler. * CU-GH PCB issue: Replace the CU-GH PCB.
Why is the return temperature higher than the flow temperature in my REMEHA Quinta Ace 160 Boiler?
If the return temperature is higher than the flow temperature in your REMEHA Boiler, it could be due to: * Reversed flow and return: Check the wiring and connectors for bad connections. * Incorrect water circulation: Check the circulation (direction, pump, valves). * Sensor issues: Ensure the sensor is correctly fitted, check the Ohmic value of the sensor, and replace the sensor if faulty.
What should I do if my REMEHA Boiler fails to connect function groups?
If the REMEHA Boiler fails to connect function groups, it could be due to: * Function group not found: Carry out an auto-detect. * Restart the boiler: Restart the boiler. * CU-GH PCB issue: Replace the CU-GH PCB.
Model | Quinta Ace 160 |
---|---|
Category | Boiler |
Output Power | 160 kW |
Max. Heat Output (80/60°C) | 160 kW |
Modulation Range | 32 - 160 kW |
Type | Condensing Boiler |
Output | 160 kW |
Warranty | 2 years |
Fuel Type | Natural Gas |
Fuel | Natural Gas |
General safety instructions for installers and end-users concerning gas and flue gas.
Additional safety guidelines and information relevant to the installation and use of the boiler.
Explains various danger levels and symbols used throughout the manual for user safety.
Provides detailed technical specifications including heat output, gas/flue gas data, and electrical characteristics.
Illustrates the physical dimensions and connection points of the boiler.
Regulations and warnings for installers concerning the boiler installation process.
Guidance on safe lifting procedures for the boiler, recommending the use of lifting aids.
Instructions and warnings for correctly mounting the boiler to the wall.
Steps for connecting the central heating circuit, expansion vessel, and condensate drain.
Procedures for making electrical connections, including the control unit and connection box.
Step-by-step guide for initial boiler setup and start-up program verification.
Instructions for adjusting gas type and checking/setting combustion parameters.
Explains how to use the control panel, including symbols and menu navigation.
Procedures for safely shutting down the boiler for extended periods.
Guide on navigating the installer menu and modifying boiler parameters.
Detailed list and description of various parameters for configuration and adjustment.
Routine checks and maintenance tasks to ensure proper boiler function.
Explanation of different error code levels (Warning, Blocking, Lock-out) and their meanings.
A checklist of tasks to be performed during the boiler's initial commissioning.
A checklist for performing annual inspection and servicing of the boiler.