How to fix return temperature sensor short circuit in REMEHA Quinta Pro 45?
N
Nicole ThompsonSep 14, 2025
If the return temperature sensor is short circuited in your REMEHA Boiler, check the wiring for bad connections. Also, check that the sensors are operating correctly and that the sensor has been correctly fitted.
C
Cynthia WrightSep 14, 2025
What to do if flow temperature sensor has open circuit in REMEHA Boiler?
F
fitzgeraldsandraSep 15, 2025
If the flow temperature sensor has an open circuit in your REMEHA Boiler, check the wiring for bad connections. Also, check that the sensors are operating correctly and that the sensor has been correctly fitted. Replace the sensor if necessary.
P
Patrick TorresSep 3, 2025
What to do if the maximum increase of the flow temperature has been exceeded in my REMEHA Boiler?
P
Penny KnappSep 3, 2025
If the maximum increase of the flow temperature has been exceeded in your REMEHA Boiler, it could be due to no flow or insufficient flow. Check the flow (direction, pump, valves). Also, check the water pressure and the cleanliness of the heat exchanger.
K
kelly95Aug 25, 2025
What to do if REMEHA Boiler water pressure is too low?
C
crystal58Aug 25, 2025
If the water pressure in your REMEHA boiler is too low, ensure that you check the water pressure and fill the boiler and the installation with water.
B
Benjamin RowlandAug 25, 2025
What to do if the water pressure is too low in my REMEHA Quinta Pro 45 Boiler?
C
Christina LarsonAug 26, 2025
If the water pressure is too low in your REMEHA Boiler, you should check the water pressure. Also, fill the boiler and the installation with water.
J
Jean WintersAug 26, 2025
What to do if REMEHA Quinta Pro 45 gas pressure is too low?
E
eric20Aug 26, 2025
If the gas pressure is too low in your REMEHA boiler, it might be due to insufficient flow or an incorrect setting on the gas pressure switch (Gps) on the SCU PCB. Check that the gas valve is fully opened, check the gas supply pressure, check whether the Gps has been correctly fitted, and replace the Gps switch if necessary.
A
Ashley LambertAug 26, 2025
What causes REMEHA Quinta Pro 45 to have five failed burner starts?
V
Vanessa AshleyAug 27, 2025
Five failed burner starts in your REMEHA boiler can be caused by no ignition spark. To solve this, check the cabling of the ignition transformer, the ionization/ignition electrode, breakdown to earth, the condition of the burner cover, the earthing, or a defective control SU PCB.
A
Alicia HallAug 27, 2025
What to do if REMEHA Quinta Pro 45 flow temperature sensor is short circuited?
C
Carolyn RobertsAug 27, 2025
If the flow temperature sensor is short-circuited in your REMEHA boiler, it may be due to a bad connection or the sensor not being connected properly. Check that the sensor has been fitted properly, ensure the sensors are operating correctly, and replace the sensor if necessary.
A
Amy ButlerAug 27, 2025
Why does REMEHA Boiler have maximum increase of the flow temperature exceeded?
N
Nicole CruzAug 27, 2025
If the maximum increase of the flow temperature has been exceeded in your REMEHA boiler, it could be due to no flow or insufficient flow, or a sensor error. Check the flow (direction, pump, valves), the water pressure, that the sensors are operating correctly, that the sensor has been fitted properly, and the cleanliness of the heat exchanger.
P
Paul HarrisonAug 27, 2025
What causes REMEHA Quinta Pro 45 temperature of heat exchanger to be too high?
E
Emma MunozAug 27, 2025
If the temperature of the heat exchanger in your REMEHA boiler is too high, it could be due to a bad connection, the sensor not being connected correctly, or no circulation. Check that the sensors are operating correctly, that the sensor has been fitted properly. If necessary, replace the sensor. Vent the air from the CH system, check the circulation (direction, pump, valves), the water pressure and the cleanliness of the heat exchanger. Also, if present, check the boiler type parameter setting.