What causes REMEHA Quinta Pro 45 temperature of heat exchanger to be too low?
D
Duane FisherAug 28, 2025
If the temperature of the heat exchanger in your REMEHA boiler is too low, it could be due to a bad connection, the sensor not being connected correctly, or no circulation. Check that the sensors are operating correctly, and that the sensor has been fitted properly. If necessary, replace the sensor. Vent the air from the CH system, check the circulation (direction, pump, valves), the water pressure, and the cleanliness of the heat exchanger. If present, check the boiler type parameter setting.
J
Jenna RobertsAug 28, 2025
What to do if REMEHA Boiler shows communication error with the SCU PCB?
T
timothydavisAug 28, 2025
If your REMEHA boiler shows a communication error with the SCU PCB, it may be due to a poor connection with the BUS or the SCU PCB not being present in the boiler. Check the wiring and carry out automatic detection.
L
Larry WalshAug 29, 2025
What causes REMEHA Boiler fan operation error?
C
Christopher WalshAug 29, 2025
A fan operation error in your REMEHA boiler could stem from a bad connection or a defective fan. Ensure adequate draw on the chimney connection and replace the fan if necessary.
C
cynthia26Aug 29, 2025
Why does REMEHA Boiler have maximum difference between the flow and return temperature exceeded?
J
Joshua SharpAug 30, 2025
If the maximum difference between the flow and return temperature is exceeded in your REMEHA boiler, it could be due to no flow or insufficient flow, or a sensor error. Check the flow (direction, pump, valves), the water pressure, that the sensors are operating correctly, that the sensor has been fitted properly, and the cleanliness of the heat exchanger.
D
Donna WilliamsAug 30, 2025
What to do if REMEHA Quinta Pro 45 phase and neutral of mains supply mixed up?
S
Stephen Mcbride PhDAug 30, 2025
If the phase and neutral of the mains supply are mixed up in your REMEHA boiler, it is likely due to incorrectly wired mains supply or a floating network or 2-phase network. Invert phase and neutral and set parameter to the correct setting.
F
framirezAug 30, 2025
Why REMEHA Boiler has no release signal?
D
Donna OliverAug 31, 2025
If your REMEHA boiler has no release signal, it could be due to an external cause, parameter error, or bad connection. Remove any external causes, check the parameters, and check the wiring.
M
Melissa HancockAug 31, 2025
What to do if the REMEHA Boiler flow temperature sensor is short circuited?
C
Christopher WebbAug 31, 2025
If the flow temperature sensor of your REMEHA Boiler is short circuited, it could be due to several reasons. First, check the wiring for any bad connections. Then, verify that the sensors are operating correctly and that the sensor has been correctly fitted. If these steps don't resolve the issue, consider replacing the sensor.
L
Larry Martin DDSAug 31, 2025
What to do if the REMEHA Quinta Pro 45 Boiler safety parameters are incorrect?
W
wballardSep 1, 2025
If the safety parameters for your REMEHA Boiler are incorrect, it might be due to a bad connection. In this case, check the wiring. Alternatively, the PSU could be defective, so consider replacing it.
S
Stephanie HughesSep 1, 2025
What to do if the REMEHA Quinta Pro 45 flow temperature sensor has an open circuit?
C
carolynorozcoSep 1, 2025
If the flow temperature sensor of your REMEHA Boiler has an open circuit, first check the wiring for any bad connections. Also, check that the sensors are operating correctly and that the sensor has been correctly fitted. If the problem persists, replace the sensor.
D
Donald SmithSep 1, 2025
How to fix REMEHA Quinta Pro 45 Boiler storage unit PSU parameter not found?
A
Amy AguilarSep 2, 2025
If the storage unit PSU parameter is not found in your REMEHA Boiler, the problem could be a bad connection. Check the wiring to resolve this issue.