(2) Default level of TOmn pin and output level after timer operation start
The change in the output level of the TOmn pin when timer output register m (TOm) is written while timer output is
disabled (TOEmn = 0), the initial level is changed, and then timer output is enabled (TOEmn = 1) before port
output is enabled, is shown below.
(a) When operation starts with master channel output mode (TOMmn = 0) setting
The setting of timer output level register m (TOLm) is invalid when master channel output mode (TOMmn = 0).
When the timer operation starts after setting the default level, the toggle signal is generated and the output
level of the TOmn pin is reversed.
Figure 6-30. TOmn Pin Output Status at Toggle Output (TOMmn = 0)
TOEmn
TOmn = 0, TOLmn = 0
TOmn = 1, TOLmn = 0
TOmn = 0, TOLmn = 1
(Same output waveform as TOLmn = 0)
TOmn = 1, TOLmn = 1
(Same output waveform as TOLmn = 0)
Default level, TOLmn setting
Independent of TOLmn setting
Port output is enabled
TO0n pin transition
Toggle Toggle Toggle Toggle Toggle
Hi-Z
Hi-Z
Hi-Z
Hi-Z
Dependent on TOmn setting
Remarks 1. Toggle: Reverse TOmn pin output status
2. m: Unit number (m = 0, 1), n: Channel number (n = 0 to 7)
<R>

Table of Contents

Other manuals for Renesas RL78/G1D

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Renesas RL78/G1D and is the answer not in the manual?

Renesas RL78/G1D Specifications

General IconGeneral
BrandRenesas
ModelRL78/G1D
CategoryComputer Hardware
LanguageEnglish

Related product manuals