2.2 Improper Use
The equipment is not suitable for use with dental CAM units!
For information concerning SILENT extraction units for CAM machines, please refer to
www.renfert.com.
Fire-promoting,easilyammable,red-hot,burningorexplosivematerialsmustnotbesuctionedintothe
device�
It is not permitted to suction liquids�
This device is not intended for private, household use�
Anyuseotherthanspeciedintheseinstructionsisdeemedimproperandconstitutesamisuseofthe
device�
The manufacturer shall not be liable for damages caused by improper use�
Only spare parts and accessories supplied or authorized by Renfert GmbH may be used with this prod-
uct� If other spare parts or accessories are used, this could have a detrimental effect on the safety of the
device, increase the risk of serious injury and lead to damage to the environment or the device itself�
2.3 Ambient Conditions for Safe Operation
The device may only be operated:
Indoors
Up to an altitude of 2,000 m above sea level,
At an ambient temperature of between 5 - 40 ºC [41 - 104 ºF] *),
At a maximum relative humidity of 80% at 31 ºC [87�8 ºF], dropping to a linear of up to 50% relative
humidity at 40 ºC [104 ºF] *),
Withmainspowerwherethevoltageuctuationsdonotexceed10%ofthenominalvalue,
Under contamination level 2 conditions,
Under over-voltage category II conditions,
*) Between 5 - 30 ºC [41 - 86 ºF] the device can be operated at a relative humidity of up to 80 %� At temperatures
between 31 - 40 ºC [87�8 - 104 ºF] the humidity must decrease proportionally in order to ensure operational readi-
ness (e�g� at 35 ºC [95 ºF] = 65 % humidity, at 40 ºC [104 ºF] = 50 % humidity)�
The device may not be operated at temperatures above 40 ºC [104 ºF]�
2.4 Ambient Conditions for Storage and Transport
Forstorageandtransportthefollowingspecicationstoambientconditionsapply:
Ambient temperature -20 – + 60 ºC [- 4 – + 140 ºF]�
Maximum relative humidity 80 %�
2.5 Hazard and Warning Information
2.5.1 General Information
If the device is not used in compliance with the supplied instructions, the safety of the device can
no longer be guaranteed.
The device may only be operated using a mains cable with the country-specic plug system. Any
necessary alterations must be carried out by a qualied electrician.
The device may only be operated if the information on the identication plate conforms to the
specications of your local mains power supply.
The device may only be plugged into outlets which are connected to the protective conductor
system.
The mains plug must be easily accessible.
Disconnect the device from the mains before carrying out work on the electrical parts.
Check connection cables (such as power supply cords), tubes and housing (i.e. the key-pad)
regularly for damage (i.e. kinks, cracks and porosity) or signs of ageing. Devices with damaged
connection cables, tubes or housing parts or other defects must not be operated!
Defective devices must be put out of service immediately. Remove the mains plug and ensure the
device is not used. Send the device for repair!
Only operate the device under supervision.
Please observe the national accident prevention regulations!
It is the responsibility of the operator that national regulations during operation and regarding a
repeated safety inspection of electrical equipment are complied with. For Germany these are the
regulation 3 by DGUV (German Statutory Accident Insurance) in relation with VDE (Association for
Electrical & Electronic Technology) 0701-0702.