66
ATOM linear encoder system
Analogue speed
20µm system - 10m/s (−3dB)
40µm system - 20m/s (−3dB)
1
All power connections should be used either to minimise voltage drop down the cable or incorporate voltage sensing.
2
The alarm signal can be output as a line driven signal or 3-state. Select the preferred option at time of ordering.
Analogue
Output signals
Digital
Function Signal Pin
Power
1
5 V 7, 8
0 V 2, 9
Incremental
A
+ 14
6
B
+ 13
5
Reference mark
Z
+ 12
4
Alarm
2
E
+ 11
3
Set-up X 1
Shield - Case
Do not connect - 10, 15
Function Signal Pin
Power
1
5 V 4, 5
0 V 12, 13
Incremental
Cosine V
1
+ 9
1
Sine V
2
+ 10
2
Reference mark
V
0
+ 3
11
Set-up V
X
6
Remote CAL CAL 14
Shield - Case
Do not connect - 7, 8, 15