MT-50 Remote Tracer Meter
RENOGY Remote Tracer Meter for Commander
Series and ViewStar Series Charge Controllers
2775 E. Philadelphia St., Ontario CA 91761
1-800-330-8678
Version 2.0

Questions and Answers:

Renogy MT-50 Specifications

General IconGeneral
Display TypeLCD
Input Voltage12V/24V
Current Measurement Range0-100A
Operating Temperature-20°C to 60°C
Backlight Time10s
Voltage Measurement Range8V~90V
Temperature Measurement Range-20°C to 60°C
Storage Temperature-4°F to 176°F

Summary

General Information

Important Safety Instructions

Provides critical safety information and symbols used in the manual.

General Safety Information

Advises on inspecting the unit, reading directions, and keeping it away from environmental hazards.

Installation Guide

Frame Wall Mount Installation

Step-by-step guide for mounting the MT-50 meter using its frame on a wall.

Operation and Display

Flush Wall Mount Installation

Instructions for installing the MT-50 meter flush with a wall surface.

Monitoring Overview

Device Information and Settings

Battery Type and Capacity Settings

Allows selection of battery type and setting of Amp-hours.

Control Parameters - Voltages

Over Voltage Disconnect and Charge Limit

Sets parameters for over-voltage disconnect and charge limit.

Over Voltage Reconnect and Equalization

Configures settings for over-voltage reconnect and equalization charge rate.

Boost and Float Charge Voltages

Sets parameters for boost charge and float charge voltage.

Boost Reconnect and Low Voltage Reconnect

Defines parameters for boost reconnection and low voltage reconnect.

Under Voltage Reconnect and Warning

Sets parameters for under voltage reconnect and under voltage warning.

Low Voltage Disconnect and Discharge Limit

Configures settings for low voltage disconnect and discharge limit.

Control Parameters - Battery and Load

Load Set - Timer Controls

Light On/Off Operation

Controls load operation based on time of day and solar voltage thresholds.

Light On+Timer Operation

Sets load operation with specific on/off times and duration.

Timer Control Operation

Enables setting specific on/off times for the load using a 24-hour clock.

Device Management

Resetting to Factory Defaults

Resets the controller to factory settings, erasing custom parameters.

Failure and Meter Parameters

Viewing Failure Logs

Provides access to view controller faults and indicators.

Status Glossary and Troubleshooting

Common Indicator Troubleshooting

Provides troubleshooting steps for common indicator failures like Load MOS-Short, Load Circuit, etc.

Troubleshooting Guide

Charging Parameters

Threshold Voltage Parameters