EasyManua.ls Logo

Rheem IKONIC RTGH-SR11i - Bypass Valve

Rheem IKONIC RTGH-SR11i
92 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
IKONIC Tankless Water Heater Service Manual
73
HOW TO REMOVE COMPONENTS
3.7 BYPASS VALVE
NOTE: : Before removing water inlet connec-
tion, turn off water to the water heater by
closing the shut off valve and drain the heater.
1. Remove user interface from the water heater.
NOTE: To remove the interface , refer to sec-
tion “3.13 Display".
2. Remove water control wiring harness from the con-
trol board (connector “G”)
3. Remove the two white Molex connectors located
rear of the user interface.
4. Remove four screws and two flange bracket.
5. Remove water inlet pipe and bypass pipe
6. Remove fastener to check valve.
NOTE: If for recirculation model, remove quick
fastener connected to water inlet.
7. Remove quick fastener connected to water control
valve.
Bypass Valve
Water Control Valve

Table of Contents

Other manuals for Rheem IKONIC RTGH-SR11i

Related product manuals