31
Program Menu
To access PROGRAM menu, press and hold SERVICE
and MODE keys simultaneously for 5 to 7 seconds until
"Language" appears on the display.
NOTE: Changes to default program congurations
could aect normal functionality of the heater.
Press the SERVICE key sequentially until the desired
program event is reached. By default, there are 12 dierent
settings that can be programmed. Additional congurations
for other add-ons are displayed when enabled. Figure 48
lists the default menus.
Set Defaults Defaults Set
Reset Faults Faults Cleared
Temp Display
Fahrenheit
Temp Display
Celsius
Spa Max Temp
50 F
Spa Max Temp
107 F
Pool Max Temp
107 F
WiFi Reset
Automaon Mode
Enabled
Automaon Mode
Disabled
Flow Monitoring
Esmaon
Flow Monitoring
Flow Sensor
Altude Normal
0 to 4500
Altude High
Above 4500
WiFi Inialized
Pool Max Temp
50 F
Pump Control
Disabled
Pump Control
Enabled
Water Chemistry
Disabled
Water Chemistry
Enabled
Langue
Français
Langue
Français
Lenguaje
Español
Lenguaje
Español
Language
English
Language
English
Figure 48. Programmable Settings
Language Selection
Initial display in PROGRAM Menus is "Language"
selection.
The UP and DOWN keys will select English, Spanish or
French language for all menus and Display messages.
Set Factory Defaults
Press the SERVICE key again. "Set Defaults" option is
displayed. To set factory defaults, press and hold SERVICE
and MODE keys simultaneously for 3 to 5 seconds until
"Defaults Set" appears.
This operation resets the operating program to its factory
default values.
Both the POOL and SPA setpoints will revert to 65°F
(18°C) and both POOL and SPA maximum temperature
settings will be 104°F (40°C). Language is set to English,
temperature display is set to Fahrenheit, Automation Mode
is enabled, Altitude to Normal, Flow monitoring is set to
Estimate, Protége Pump Control and other add-ons are
disabled. The Control Lockout PIN will be cleared and
the control will resume normal operation. See "Control
Lockout" section on page 34.
Reset Faults
Press the SERVICE key again. "Clear Faults" appears
on the digital display. To clear fault history press and
hold SERVICE and MODE keys simultaneously for 3 to 5
seconds until "Faults Cleared" appears.
Temperature Display
Press the SERVICE key again. "Temp Display" appears
on the digital display. The UP or DOWN keys will select
Fahrenheit or Celsius on the temperature display. Choose
the desired temperature scale.
Spa Setpoint Maximum Adjustment
Press the SERVICE key until "Spa Max. Temp" appears
on the digital display. Using the UP and DOWN keys will
change the Maximum Temperature Setting to your desired
value. The control can be set for a maximum of 107°F
(42°C).
Pool Setpoint Maximum Adjustment
Press the SERVICE key until "Pool Max. Temp" appears
on the digital display. Using the UP and DOWN keys will
change the Maximum Temperature Setting to your desired
value. The control can be set for a maximum of 107°F
(42°C).
WARNING: Ensure to properly setup pool and spa max
setpoint limits. Setpoint should never exceed above
107° F (42°C).