13. AUXILIARY CONTROL
OUTPUT
The AVIA heater o󰀨ers an integrated dry contact relay for
local and remote control of ON/OFF devices like pumps,
water features, valves and lights.
PUMPS
WATER FEATURES
LIGHTS
Figure 142. Device Relay Integration
Auxiliary output is available in terminal P9 “AUX”. Use the
supplied harness to control ON/OFF functions or power
switching.
COM
NO
NC
AUXILIARY RELAY
OUTPUT
TEMP
INTPUT
TEMP
AUX
POWER BLOWER
P2 P1 P9
Figure 143. Auxiliary Terminal
AUX terminal can be used as direct control or as pilot
relay to a higher rating relay or power contactor. Table S
describes Auxiliary output terminals and ratings.
Terminal Wire AC Rating DC Rating
Common Black
250V Max,
3A
30V Max,
3A
Normally Open Black and Red
Normally Closed Black and White
Table S. Auxiliary Terminals and Ratings
A
CAUTION: Do not exceed Auxiliary relay rating.
Check power requirements of any electric component
connected to this device, following the applicable
installation norms and requirements.
Use the knockout holes located next to water inlet panel to
route auxiliary harness inside the cabinet to the controller
board. See Figure 144.
ROUTE HARNESS
FROM KNOCKOUT
TO CONTROL BOARD
TO AUXILIARY
DEVICE
Figure 144. Route Communication Harness
It is recommended to use a 1/2" NPT liquid tight cord grip
inserted in the panel knockout hole for better sealing.
NOTE: Use your smartphone camera to access detailed
instructions for Auxiliary output scheduling with
Raymote. https://www.raypak.com/support/tech-corner/
raymote-automation/