531
D
Fusing Fan Motor Error
A LOCK signal is not detected for more than ten seconds while the motor START signal is on
and if this error occurs twice consecutively, this SC is issued.
• Disconnected or defective motor harness.
•
Defective LSU fan motor
1. Check or replace the motor harness.
2. Replace the fusing fan motor.
532
D
Air Intake Fan Motor Error
A LOCK signal is not detected for more than ten seconds while the motor START signal is on
and if this error occurs twice consecutively, this SC is issued.
• Disconnected or defective motor harness.
•
Defective air intake fan motor
1. Check or replace the motor harness.
2. Replace the air intake fan motor.
533
D
PSU Fan Motor Error
A LOCK signal is not detected for more than ten seconds while the motor START signal is on
and if this error occurs twice consecutively, this SC is issued.
• Disconnected or defective motor harness.
•
Defective PSU fan motor
1. Check or replace the motor harness.
2. Replace the PSU fan motor.