541
A
Thermistor Error
The thermistor output is less than 0°C for 6 seconds.
Disconnected thermistor
Defective harness connection
1. Check the harness connection of the thermistor.
2. Replace the fusing unit.
Execute "SC Reset; Fusing SC" with SP5-810-001 to recover the machine after
completing the recovery procedure. Otherwise, the machine continues to issue this SC
code and cannot be operated.
542
A
Print Ready Temperature Error
The heating roller temperature increase during a set time is not correct.
The fusing temperature does not reach the print ready temperature within a set time after
the fusing lamp has turned on.
Defective thermistor
Incorrect power supply input at the main power socket
Defective fusing lamp
1. Check the voltage of the wall outlet.
2. Replace the fusing unit
3. Replace the fusing lamp.
Execute "SC Reset; Fusing SC" with SP5-810-001 to recover the machine after
completing the recovery procedure. Otherwise, the machine continues to issue this SC
code and cannot be operated.