543
A
High Temperature Detection Error
This SC is issued if one of following conditions occurs:
The thermistor (center) detects 245°C or thermistor (end) detects 230°C.
The thermistor (center) detects a 14°C increment or more for five seconds at 220°C or
more or the thermistor (end) detects a 9°C increment or more for five seconds at 160°C
(Warming Up), 170 °C (Standby), or 180°C (Print) or more.
Defective I/O control (EGB)
Defective EGB
1. Replace the EGB
Execute "SC Reset; Fusing SC" with SP5-810-001 to recover the machine after
completing the recovery procedure. Otherwise, the machine continues to issue this SC
code and cannot be operated.
545
A
Heating Lamp Full-Power Error
The fusing lamp is fully-powered for a certain time while the fusing unit stays in the stand-by
mode and is not rotating.
Deformed thermistor
Thermistor not in the correct position
Defective fusing lamp
1. Replace the fusing unit.
2. Replace the fusing lamp.
Execute "SC Reset; Fusing SC" with SP5-810-001 to recover the machine after
completing the recovery procedure. Otherwise, the machine continues to issue this SC
code and cannot be operated.
547
D
Zero Cross Error
The zero cross signal is not detected for three seconds even though the fusing lamp relay is on
after turning on the main power or closing the front door.
Defective fusing lamp relay
1.
Turn the main power switch off and on.
SC Conditions
199
6
SC543
RTB 16
RTB 20