• Wrong engine board installed
•
Wrong controller board installed
1. Check the type of EGB and controller board.
2. Replace the EGB.
3. Replace the controller board.
SC8xx
816
D
Energy save I/O subsystem error
An error was detected in the signal from the ASIC (controller board) which controls the STR
(Suspend to RAM) function.
Note: STR is a feature of this machine that minimizes energy consumption while the machine
is in the energy saver mode.
• Reboot the machine.
•
Replace the controller board.
-5
SCS
Machine attempted to enter STR mode before engine is OFF.
-39
Sub System
Error occurred during system start up.
-50
Hardware
Printer version only. Not used for this machine.
-67 NCS (Network Control Service)
An error occurred in the access control port list:
•
Number of registrations exceeded 125
• Data notifications exceeded 12
• Data extension incorrect
-79
Sub System
Message mismatch.
SC Conditions