10 August, 2001 SERVICE PROGRAM MODE
4-21
Service
Tables
2
Mode Number/Name Function/[Setting]
Test Pattern Printing902*
3 Prints the test patterns. Select the number of the test
pattern that you want to print (☛ 4.2.3).
When adjusting the printing registration, select no.10
(Trimming Area Pattern).
[0 ~ 41 / 0 / 1 step]
Tailing Correction
1 Shift Value Shifts the image across the page at the interval
specified by SP2-906-2.
When making many copies of an original that contains
vertical lines (such as a table), separation may not
work correctly, then a tailing image will occur (ghosts
of the vertical lines will continue past the bottom of the
table). This SP prevents this problem.
[0.0 ~ 1.0 / 0.0 / 1 mm/step]
906*
2 Interval Changes the interval for the image shift specified by
SP2-906-1.
[1 ~ 10 / 0 / 1 page/step]
Line Width Correction
1 Text Mode
Adjusts the line width. The value “5” means that line
width correction is disabled. A number smaller than 5
makes lines thinner. A number bigger than 5 makes
lines thicker.
Thinnest Thickest
0 – 1 – 2 – 3 – 4 – 5 – 6 – 7 – 8 – 9 – 10
[0 ~ 10 / 5 / 1 step]
2 Photo Mode
[0 ~ 10 / 6 / 1 step]
3 Text/Photo Mode
[0 ~ 10 / 5 / 1 step]
4 Pale Mode
[0 ~ 10 / 5 / 1 step]
907*
5 Generation Mode
[0 ~ 10 / 5 / 1 step]
Forced Toner Supply908
Forces the toner bottle to supply toner to the toner
supply unit.
Press Execute on the touch panel to start.
During this process, the machine supplies toner until
the toner concentration in the development unit
reaches a standard level. However, if the toner
concentration does not reach a standard level, the
machine supplies toner for 2 minutes maximum.
Main Scan Magnification
1 Copy - Short Edge Feed Adjusts the main scan magnification in copy mode
when the machine feeds the paper in the short edge
feed orientation.
[-0.5 ~ 0.5 / 0.0 / 0.1%/step]
2
Printer – Short Edge
Feed
Adjusts the main scan magnification in printer mode
when the machine feeds the paper in the short edge
feed orientation.
[-0.5 ~ 0.5 / 0.0 / 0.1%/step]
909*
3 Copy – Long Edge Feed
Adjusts the main scan magnification in copy mode
when the machine feeds the paper in the long edge
feed orientation.
[-0.5 ~ 0.5 / 0.0 / 0.1%/step]