SERVICE CALL CONDITIONS 10 August, 2001
7-6
Code No. Symptom Possible Cause
Communication timeout error between
SBCU and finisher
620 B
The SBCU cannot receive a response
within 100 ms after 3 attempts after
sending data to the finisher.
Serial line connecting SBCU and
finisher unstable
External noise
SBCU board and finisher main board
connection defective or loose
Finisher main board defective
SBCU board defective
Communication timeout error between
SBCU and finisher
621 B
A break (low) signal was received from
the finisher.
Serial line connecting SBCU and
finisher unstable
External noise
Communication failure with CSS (RSS)630 C
The communication from the copier
was detected as abnormal at the CSS
center. This error occurs when the
acknowledge signal from the LADP
does not complete normally.
Occurred with an SC call, CC call,
supply management call, user call, or
CE call.
Timeout while no response from the
LADP, and abnormal signal on the
RS-485 line between PI and LADP.
SBCU control data transfer checksum
error
640 C
A sampling of control data sent from the
SBCU to the controller reveals a
checksum error. Only the logging count
is performed.
Controller board defective
External noise
SBCU board
defective
SBCU control data transfer abnormal641 C
A sampling of the control data sent from
the SBCU reveals an abnormality.
Controller board defective
External noise
SBCU board defective
Communication timeout error between
SBCU and duplex unit
650 B
The SBCU cannot receive a response
within 1 second from the duplex unit.
Serial line connecting SBCU and
duplex unit unstable
External noise
SBCU board and duplex main board
connection defective or loose
Duplex main board defective
SBCU board defective
Engine response error670 D
After powering on the machine, a
response is not received from the
engine within 30 seconds.
SBCU installed incorrectly
SBCU defective
Controller board defective
Controller-to-operation panel
communication error at startup
672 D
After powering on the machine, the
communication circuit between the
controller and the operation panel is not
opened, or communication with
controller is interrupted after a normal
startup.
Controller stall
Controller board installed incorrectly
Controller board defective
Operation panel connector loose or
defective
Finisher jogger motor error (500-sheet
finisher)
720 B
The finisher jogger H.P sensor remains
de-activated for a certain time when
returning to home position.
The finisher jogger H.P sensor remains
activated for a certain time when
moving away from home position.
Jogger H.P sensor defective
Jogger motor defective