SERVICE CALL CONDITIONS 10 August, 2001
7-8
Code No. Symptom Possible Cause
Finisher shift motor error (1000-sheet
finisher)
732 B
Roller shift does not finish within a
certain time after the shift motor turned
on.
Shift motor defective
Shift tray HP sensor defective
Bridge communication error791 B
The SBCU cannot communicate with
the bridge unit properly when the
finisher is installed.
Poor connection between the main
machine and bridge unit
SBCU board defective
Finisher connection error792 B
The SBCU cannot communicate with
the finisher properly when the bridge
unit is installed.
Poor connection between the finisher
and bridge unit
SBCU board defective
Interchange communication error793 B
The SBCU cannot communicate with
the interchange unit properly when the
duplex unit is installed.
Poor connection between the
interchange unit and main machine
SBCU board defective
Startup without video output end error
(K)
800 D
Video transfer to the engine is started,
but the engine did not issue a video
transmission end command within the
specified time.
Controller board defective
Startup without video input end (K)804 D
A video transmission was requested
from the scanner, but the scanner did
not issue a video transmission end
command within the specified time.
Controller board defective
Watchdog error818 D
The CPU does not access the
watchdog register within a certain time.
Controller
board defective
Software malfunction – download
controller firmware again
Kernel mismatch error819 D
Software bug
Download controller firmware again
Self-Diagnostic Error: CPU820 D
The central processing unit returned an
error during the self-diagnostic test.
Controller board defective
Download controller firmware again
Self-Diagnostic Error: ASIC821 D
The ASIC returned an error during the
self-diagnostic test because the ASIC
and CPU timer interrupts were
compared and determined to be out of
range.
Controller board defective
Self-Diagnostic Error: HDD822 D
The hard disk drive returned an error
during the self-diagnostic test.
HDD defective
HDD connector defective
Controller board defective
Self-diagnostic Error: NIB823 D
The network interface board returned
an error during the self-diagnostic test.
Network interface board defective
Controller board defective
Self-diagnostic Error: NVRAM824 D
The resident non-volatile RAM returned
an error during the self-diagnostic test.
Replace the NVRAM on the
controller board
Replace the controller board