SERVICE CALL CONDITIONS 10 August, 2001
7-10
Code No. Symptom Possible Cause
Startup without HD data lead
863 B
Data stored on the hard disk is not read
correctly.
A bad sector occurred during operation
of the HDD
HD data CRC error864 D
During operation of the HD, the HD
responded with a CRC error.
Data transfer was abnormal in the data
read from the HDD.
HD access error865 D
The hard disk detected an error.
Replace the controller board
Electronic total counter error900 D
The value of the total counter has
already exceeded 9999999
Replace the NVRAM on the controller
board
Mechanical total count error901 D
The SBCU board cannot receive the
mechanical total count data.
Mechanical total counter defective
F-gate error at write request951 B
After the IPU receives an F-gate signal,
it receives another F-gate signal.
Download controller firmware
SBCU board defective
Scanner setting error953 B
The IPU does not respond with the
scanner setting signal required to start
scanning processing.
Download controller firmware
Printer setting error954 B
The IPU does not respond with the
settings that are required to start image
processing by the printer.
Replace the IPU board
Replace the controller board
Download the controller firmware
Memory setting error955 B
The IPU does not respond with the
settings that are required to start image
processing using the memory.
Replace the IPU board
Replace the controller board
Download the controller firmware
Printer ready error964 B
The printer ready signal is not
generated within 17 seconds after the
IPU received the print start signal.
Replace the IPU board
Replace the controller board
Download the controller firmware
Print image data transfer error984 D
The image transfer from the controller
to the engine via the PCI bus does not
end within 15 s after starting.
Controller board defective
SBCU board defective
Connectors between SBCU and
controller loose or defective
Software write parameter setting error986 D
An unstable area at the storage
destination in the settings table is set at
NULL for the parameter received by the
write module.
Download controller firmware again