4-2
Confidential
1.1 Setting by Spec, Setting Serial Number and
Entering Adjusted Value of Laser Unit
<Operating Procedure>
(1) Enter the maintenance mode.
(2) Connect the machine to your computer using the USB cable.
When you use the main PCB ASSY that has been used even once in the market (the
machine is at factory shipping state (Shipping state=ON).), perform the following steps
(3) and (4). When the new main PCB ASSY is used, proceed to step (5).
(3) Open the temporary folder and
double-click
“MemoryAccessTool.exe”. The
screen shown on the right appears.
(4) Click the [Execute] and close the
Maintenance Exception Tool screen.
Wait for 5 seconds or longer and
then proceed to the next step.
(5) Double-click “SvSettingTool.exe”. The screen shown on the right appears.
(6) Check that the USB port connected with the
machine is displayed in the box (A).
(7) Enter all or part of the model name in the box
(B) and press the [Find a model]. Series name
and model name are displayed in the box (C).
(8) Click the [Input information]
shown as (E).
The Input Information screen
shown on the right appears.
(9) Click the [Setting by Spec] in
the box (F). Set Spec Code
screen appears.
Enter the 4-digit country code
in the box (G), and click the
[Set] shown as (H).
“Set[****]” and entered value
appears on the “Setting by Spec” line in (F). (“****” indicates the spec code entered.)
Note:
• If the [Execute] on the Memory access tool is pressed once, it is valid as long as the
machine does not quit the maintenance mode.
• If the BRMODELCODE, the Serial, and the ID fields are displayed incorrectly, quit the
maintenance mode and then restart from step (1).