5.System Maintenance
117
[170 to 200 / 185 / 5°C/step]
Adjusts the fusing temperature for envelopes.
[170 to 200 / 185 / 1°C/step]
Adjusts the fusing temperature for thin paper.
[155 to 180 / 170 / 1°C/step]
Adjusts the fusing temperature in the low power mode.
[80 to 135 / 120 / 1°C/step]
Adjusts the fusing temperature in the standby mode.
[120 to 175 / 155 / 1°C/step]
Adjusts the fusing temperature for thick 2 paper.
[170 to 200 / 185 / 1°C/step]
Adjusts the fusing temperature for thick 1 paper.
[175 to 200 / 185 / 1°C/step]
Adjusts the amount of paper buckle at the registration roller for each
tray and paper type.
[-8 to 8 / -2 (Default) / 1mm/step]
[-8 to 8 / 0 (Default) / 1mm/step]
[-8 to 8 / -2 (Default) / 1mm/step]
[-8 to 8 / -2 (Default) / 1mm/step]
[-8 to 8 / 0 (Default) / 1mm/step]
[-8 to 8 / -2 (Default) / 1mm/step]
[-8 to 8 / -2 (Default) / 1mm/step]
[-8 to 8 / 0 (Default) / 1mm/step]
[-8 to 8 / -2 (Default) / 1mm/step]
[-8 to 8 / 0 (Default) / 1mm/step]
[-8 to 8 / 0 (Default) / 1mm/step]
[-8 to 8 / 0 (Default) / 1mm/step]