15
20167399
GB
Installation
5.5 Servomotor (SQN90...)
Important notes
All interventions (assembly and installation operations,
assistance, etc.) must be carried out by qualified personnel.
Falls and collisions can negatively affect the safety
functions. In this case, the servomotor must not be
operated, even if it displays no evident damage.
Fully disconnect the burner from the mains when working
near terminals and servomotor connections.
Condensation and exposure to water are not allowed.
For safety reasons, the servomotor must be checked after
long periods of non-use.
Technical data
Tab. F
ATTENTION
To avoid accidents, material or environmental
damage, observe the following instructions!
Avoid opening, modifying or forcing the
servomotor.
Mains voltage AC 220V-15%...AC 240V+10%
AC 100V-15%...AC110V+10%
Mains frequency 50 / 60 Hz +/- 6%
Power absorption 8 VA
Motor Synchronous
Drive angle up to 90°
Cable connection terminal board for 0.5 mm
2
(min.)
and 2.5 mm
2
(max)
Rotation direction Anticlockwise
Operation time 24 s. at 9
Weight approx. 0.55 kg
Breakdown voltage 24...250V AC
Safety class II to DIN EN 60730
Environmental conditions:
Storage
Climatic conditions
Mechanical conditions
Temperature
Humidity
DIN EN 60721-3-1
Class 1K3
Class 1M2
-20...+60°C
< 95 % RH
Fig. 9