INSTALLATION
11
2
INSTALLATION
9
Ensure that the installation and operation sites are prop-
erly ventilated in order to disperse any gas leaks that could
cause flames during activities with intense heat generation
and high temperature.
9
Avoid proximity to sources of ignition in continuous op-
eration (open flames, gas household appliances, electric
stoves, lit cigarettes, etc).
9
Use equipment suitable for the system refrigerant.
9
Use an electronic leak finder properly calibrated for the sys-
tem refrigerant.
0
It is forbidden to use leak finders with halogen lamps.
2.1
Receiving the product
R AARIA START is supplied in a single pack, protected by a
cardboard box and by polystyrene elements.
The following material is placed inside the packaging, below the
unit
Document envelope:
Instruction's book for the installer and for the Technical
Service in Italian
Instruction's book for the installer and for the Technical
Service in English
Warranty/Spare parts labels.
energy label
etichetta gas refrigerante
contact sheet
It is also supplied as kit:
Condensate outlet hose.
4 x vibration dampers
screws to connect refrigerant connections cover
9
The Instruction book comes with the equipment and it
should be taken, read and kept carefully.
9
The document envelope must be kept in a safe place. Any
duplicate must be requested from Riello S.p.A. which re-
serves to charge the cost.
2.2
Labels positioning
A Package label
B Transport label
B
A
A
2.3
Dimensions and weight
L
P
H
Model 25 35 50 70
Packaging dimensions
H 620 620 685 780 mm
L 920 920 963 1046 mm
P 351 351 413 460 mm
Weight 30,0 31,0 41,5 56,0 kg
L
L1
P
H
Model 25 35 50 70
Product dimensions
H 540 540 614 697 mm
L 780 780 820 890 mm
L1 893 988 mm
P 245 245 338 353 mm
Weight 27,0 28,0 37,8 51,0 kg
2.4
Storage
If the product is stored in a room before installation check:
there aren't continously operating ignition sources (open
flames, gas appliances, electric heaters,..) within a radius
of 2.5 m.
the floor area is larger than 3 m²
there is adequate ventilation
840 840