GENERAL INFORMATION
8
1.7
Technical specifications
Prestazioni in abbinamento ad AMW ST
Model AMW 25 ST AMW 35 ST AMW 50 ST AMW 70 ST
Cooling performance [A35 / A27]
(1)
Capacity at rated air flow 2,60 3,60 5,20 7,00 kW
Absorbed power at rated air flow 0,80 1.11 1,61 2,16 kW
EER 3,23 kW/kW
Capacity at maximum air flow 3,40 4,20 6,80 8,50 kW
Absorbed power at maximum air flow 1,20 1,60 2,00 2,90 kW
Capacity at minimum air flow 0,80 1,00 1,30 2,20 kW
Absorbed power at minimum air flow 0,30 0,40 0,70 kW
Energy data
(2)
SEER 6,20 6,80 7,10 kW/kW
Energy class A++
Annual energy consuption 147 186 268 350 kWh/annum
Heating performance [A7 / A20]
(3)
Capacity at rated air flow 3,40 4,20 6,00 8,10 kW
Absorbed power at rated air flow 0,91 1,13 1,61 2,18 kW
COP 3,71 kW/kW
Capacity at maximum air flow 4,60 5,40 6,90 10,00 kW
Absorbed power at maximum air flow 1,50 1,60 2,35 2,90 kW
Capacity at minimum air flow 1,00 1,10 1,40 2,40 kW
Absorbed power at minimum air flow 0,30 0,40 0,52 0,70 kW
Enery data for Average climatic profile
(4)
Pdesign at -10 °C 2,40 3,20 5,20 5,60 kW
SCOP 4,00 kW/kW
Energy class A+
Annual energy consuption 839 1123 1819 1963 kWh/annum
Energy data for Warm climatic profile
(4)
Pdesign at +2 °C 1,30 1,70 2,80 3,30 kW
SCOP 4,90 4,60 5,30 kW/kW
Energy class A++ A+++
Annual energy consuption 373 517 734 872 kWh/annum
(1) Outdoor air: 35 °C D.B., Indoor air: 27 °C D.B. / 19 ° W.B.
(2) In compliance with 626/2011 regulation
(3) Outdoor air: 7 °C D.B. / 6 °C W.B., Indoor air: 20 °C D.B.
(4) In compliance with EU 206/2012 regulation