9
20068428
Technical description of the burner
4.5 Electrical data
Tab. E
Tab. F
Tab. G
Model RS 70/E RS 100/E
Main electrical supply
Control circuit power supply
3 ~ 230/400V +/-10% 50Hz
1N ~ 230V +/-10% 50Hz
3 ~ 230/400V +/-10% 50Hz
1N ~ 230V +/-10% 50Hz
Fan motor IE3 Hz
rpm
V
kW
A
50
2890
220-240 / 380-415
2.2
8.0 - 4.6
50
2895
230 - 400
4.5
15.0 - 8.7
Ignition transformer V1 - V2
I1 - I2
230 V - 1 x 8 kV
1 A - 20 mA
Absorbed electrical power kW max 1.9 2.3
Protection level IP44
Model RS 130/E RS 190/E
Main electrical supply
Control circuit power supply
3 ~ 230/400V +/-10% 50Hz
1N ~ 230V +/-10% 50Hz
3 ~ 230/400V +/-10% 50Hz
1N ~ 230V +/-10% 50Hz
Fan motor IE3 Hz
rpm
V
kW
A
50
2890
220-240 / 380-415
2.2
8.0 - 4.6
50
2895
230 - 400
4.5
15.0 - 8.7
Ignition transformer V1 - V2
I1 - I2
230 V - 1 x 8 kV
1 A - 20 mA
Absorbed electrical power kW max 3.0 5.5
Protection level IP44
Model RS 250/E MZ
Main electrical supply
Control circuit power supply
3 ~ 230/400V +/-10% 50Hz
1N ~ 230V +/-10% 50Hz
Fan motor IE3 Hz
rpm
V
kW
A
50
2935
230 - 400
5.5
17.7 - 10.2
Ignition transformer V1 - V2
I1 - I2
230 V - 1 x 8 kV
1 A - 20 mA
Absorbed electrical power kW max 6.5
Protection level IP44