RIGOL
Programming Guide for DM3058
3-10
example: 8.492853e-05, unit is V.
4. :measure:voltage:DC
Command Format:
:measure:voltage:DC{<range>|MIN|MAX|DEF}
Function:
The command sets the measuring range of DC voltage and resolution.
Parameters:
Type
Range of Values
Default
discrete
{0|1|2|3|4}
0
Explanations:
To set the measuring range of DC voltage and the resolution at the same time.
The measure mode will be changed into manual when setting range.
For the reference ranges and resolutions please refer to table 3-1.
Table 3-1 The DC voltage range and the resolution
Parameter
Range
Resolution
0
200 mV
100 nV
1
2 V
1 μV
2
20 V
10 μV
3
200 V
100 μV
4
1000 V
1 mV
MIN
200 mV
100 nV
MAX
1000 V
1 mV
DEF
20 V
10 μV
Examples:
To set the measuring range of DC voltage as 200.0 V:
:measure:voltage:DC3
To set the measuring range of DC voltage as minimum.
:measure:voltage:DCMIN or :measure:voltage:DC0