RIGOL
© 2008 RIGOL Technologies, Inc.
Programming Guide for DS1000/DS1000CA Series
2-48
Trigger Commands
Trigger control commands
The trigger determines when the oscilloscope starts to acquire data and display a
waveform. When a trigger is set up properly, it converts unstable displays into
meaningful waveforms.
When the oscilloscope starts to acquire a waveform, it collects enough data so that
it can display the waveform to the left of the trigger point. The oscilloscope
continues to acquire data while waiting for the trigger condition to occur. After it
detects a trigger, the oscilloscope continues to acquire enough data so that it can
display the waveform to the right of the trigger point.
Trigger control commands include:
:TRIGger:MODE
:TRIGger<mode>:SOURce
:TRIGger<mode>:LEVel
:TRIGger<mode>:SWEep
:TRIGger<mode>:COUPling
:TRIGger:HOLDoff
:TRIGger:STATus?
We will give specific explanations for each command in the following part.