RIGOL
© 2008 RIGOL Technologies, Inc.
Programming Guide for DS1000/DS1000CA Series
Returned Format:
Query returns “POSITIVE” or “NEGATIVE”. The double quotes are not returned.
Example:
:TRIGger:VIDEO:POLarity□POSitive Set the Video polarity as POSitive
:TRIGger:VIDEO:POLarity? Query returns “POSITIVE”
5.3 :TRIGger:VIDEO:STANdard
Command Format:
:TRIGger:VIDEO:STANdard□{NTSC|PALSecam}
Explanation:
The command is to set the video type as NTSC or PAL/SECAM.
Quert Format:
:TRIGger:VIDEO:STANdard?
Returned Format:
Query returns “NTSC” or “PAL/SECAM”. The double quotes are not returned.
Example:
:TRIGger:VIDEO:STANdard□PALSECAM Set the video type as PAL/SECAM
:TRIGger:VIDEO:STANdard? Query returns “PAL/SECAM”
5.4 :TRIGger:VIDEO:LINE
Command Format:
:TRIGger:VIDEO:LINE□<value>
Explanation:
The command is to set up number of synchronous appointed lines.
The range of <value>: 1~525 for NTSC standard
The range of <value>: 1~ 625 for PAL standard
Query Format:
:TRIGger:VIDEO:LINE?
Returned Format: