RIGOL
© 2008 RIGOL Technologies, Inc.
Programming Guide for DS1000/DS1000CA Series
2-64
6. Set the Alternate trigger condition
When alternate trigger is on, the trigger sources come from the two vertical
channels. This mode can be used to observe two non-related signals. You can
choose two different trigger modes for individual channels. The options are as
follows: Edge, Pulse, Slope and video.
6.1 :TRIGger:ALTernation:SOURce
Command Format:
:TRIGger:ALTernation:SOURce<src>
Explanation:
The command is to choose the source channel. <src> can be CHANnel1 or CHANnel2.
Query Format:
:TRIGger:ALTernation:SOURce?
Returned Format:
Query returnsCH1 or CH2. The double quotes are not returned.
Example:
:TRIGger:ALTernation:SOURce□CHANNEL2 Choose Channel 2 as the source
:TRIGger:ALTernation:SOURce? Query returns CH2
6.2 :TRIGger:ALTernation:TYPE
Command Format:
:TRIGger:ALTernation:TYPE<value>
Explanation:
The command is to set up trigger type.
<type> can be EDGE, PULSe, SLOPe or VIDEO.
Query Format:
:TRIGger:ALTernation:TYPE?
Returned Format:

Other manuals for Rigol DS1000 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Rigol DS1000 Series and is the answer not in the manual?

Rigol DS1000 Series Specifications

General IconGeneral
BrandRigol
ModelDS1000 Series
CategoryTest Equipment
LanguageEnglish

Related product manuals