RIGOL Chapter 2 Command System
2-208 MSO7000/DS7000 Programming Guide
:TRIGger:SPI (Option)
Command List:
:TRIGger:SPI:SCL
:TRIGger:SPI:SDA
:TRIGger:SPI:WHEN
:TRIGger:SPI:WIDTh
:TRIGger:SPI:DATA
:TRIGger:SPI:TIMeout
:TRIGger:SPI:SLOPe
:TRIGger:SPI:CLEVel
:TRIGger:SPI:DLEVel
:TRIGger:SPI:SLEVel
:TRIGger:SPI:MODE
:TRIGger:SPI:CS
:TRIGger:SPI:SCL
Syntax
:TRIGger:SPI:SCL <source>
:TRIGger:SPI:SCL?
Description
Sets or queries the channel source of the clock line of SPI trigger.
Parameter
Name
Type
Range
Default
<source>
Discrete
{D0|D1|D2|D3|D4|D5|D6|D7|D8|D9|D10|D1
1|D12|D13|D14|D15|CHANnel1|CHANnel2|C
HANnel3|CHANnel4}
CHANnel1
Return
Format
The query returns D0, D1, D2, D3, D4, D5, D6, D7, D8, D9, D10, D11, D12, D13, D14,
D15, CHAN1, CHAN2, CHAN3, or CHAN4.
Example
:TRIGger:SPI:SCL CHANnel1 /*Sets the channel source of the clock line to CH1.*/
:TRIGger:SPI:SCL? /*The query returns CHAN1.*/
:TRIGger:SPI:SDA
Syntax
:TRIGger:SPI:SDA <source>
:TRIGger:SPI:SDA?
Description
Sets or queries the channel source of the data line of SPI trigger.
Parameter
Name
Type
Range
Default
<source>
Discrete
{D0|D1|D2|D3|D4|D5|D6|D7|D8|D9|D10|D1
1|D12|D13|D14|D15|CHANnel1|CHANnel2|C
HANnel3|CHANnel4}
CHANnel2
Return
Format
The query returns D0, D1, D2, D3, D4, D5, D6, D7, D8, D9, D10, D11, D12, D13, D14,
D15, CHAN1, CHAN2, CHAN3, or CHAN4.
Example
:TRIGger:SPI:SDA CHANnel2 /*Sets the channel source of the data line to CH2.*/
:TRIGger:SPI:SDA? /*The query returns CHAN2.*/