EasyManua.ls Logo

Rigol DS7024 User Manual

Rigol DS7024
374 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
User Guide
MSO7000/DS7000 Series Digital
Oscilloscope
Jul. 2020
RIGOL TECHNOLOGIES CO., LTD.

Table of Contents

Other manuals for Rigol DS7024

Question and Answer IconNeed help?

Do you have a question about the Rigol DS7024 and is the answer not in the manual?

Rigol DS7024 Specifications

General IconGeneral
Bandwidth200 MHz
Channels4
Sample Rate2 GSa/s
Vertical Sensitivity1 mV/div to 10 V/div
Timebase Range1 ns/div to 1000 s/div
Input CouplingAC, DC, GND
Operating Temperature0 °C to +50 °C
Display10.1 inch
Vertical Resolution8 bit
Trigger TypesEdge, Pulse, Video, Window
Serial Bus Triggering and DecodingI2C, SPI, UART, CAN
InterfacesUSB, LAN, HDMI
Input Impedance1 MΩ

Summary

Safety Requirement

General Safety Summary

Precautions for avoiding personal injury or damage to the instrument and connected products.

Measurement Category

Ventilation Requirement

Explains airflow requirements and clearance needed for proper cooling.

MSO7000/DS7000 Series Overview

Chapter 1 Quick Start

Chapter 2 To Set the Vertical System

To Adjust the Vertical Scale

Explains how to adjust the voltage value per grid in the vertical axis for waveform display.

Chapter 3 To Set the Horizontal System

To Adjust the Horizontal Time Base

Explains how to adjust the time of each grid in the horizontal direction of the screen.

To Adjust the Horizontal Position

Details how to adjust the trigger point position relative to the screen center.

Chapter 4 To Set the Sample System

Acquisition Mode

Details the four acquisition modes: Normal, Average, Peak, and High Resolution.

Chapter 5 To Trigger the Oscilloscope

Trigger Source

Details selecting trigger sources from analog channels, digital channels, EXT, or AC Line.

Trigger LEVEL/Threshold Level

Explains how to adjust trigger level/threshold based on trigger source type.

Trigger Mode

Describes the three trigger modes: Auto, Normal, and Single.

Chapter 6 Operations and Measurements

Math Operation

Explains performing arithmetic, logic, function, and filter operations on waveforms.

Auto Measurement

Covers quick measurements after AUTO setting for various waveform parameters.

Cursor Measurement

Explains how to use cursors (X and Y) for measuring values on waveforms.

Chapter 7 Digital Voltmeter (DVM) and Frequency Counter

Chapter 10 Digital Channel

Chapter 11 Protocol Decoding

Chapter 13 Pass/Fail Test

To Create a Mask

Details self-defining the pass/fail test mask using screen or cursor regions and tolerance ranges.

Chapter 18 Store and Load

Chapter 19 System Utility Function Setting

Self-calibration

Explains the self-calibration program for optimal measurement accuracy.

Chapter 20 Remote Control

Remote Control via USB

Guides on connecting the device and installing USB drivers for remote control.

Remote Control via LAN

Details connecting via LAN, configuring network parameters, and searching for device resources.

Remote Control via GPIB

Covers connecting via GPIB, installing drivers, and searching for device resources.

Chapter 21 Troubleshooting

No waveform of the signal is displayed on the screen

Troubleshooting steps for issues where no signal waveform is displayed.

Related product manuals