Chapter 11 Protocol Decoding    RIGOL 
MSO7000/DS7000 User Guide  11-23 
screen to select it. The available choices include "Packets", "Details", 
and "Payload". You can also tap "Packets", "Details", or "Payload" at 
the top of the event table to select it. 
If you select "Packets", the decoded data (MISO and/or MOSI), time, 
and error information (MISO and/or MOSI) are displayed in the event 
table. If you select "Details", the detailed data in the specified row will 
be displayed in the event table. If "…" appears in the row of data, it 
indicates that the decoded data are not fully displayed. At this time, 
you can view the details in the "Packets" view. If you select "Payload", 
all data in the specified column will be displayed in the event table. If 
"…" appears in the specified column of data, it indicates that the 
decoded data are not fully displayed. At this time, you can view the 
details in the "Packets" view.   
➢  Export: If you select "Packets", you can export time and the 
corresponding decoded data. Press Export, the save setting menu is 
displayed. You can export the data table of the packets to the internal 
or external USB storage device (when detected) in CSV format. For 
detailed saving operation, refer to descriptions in "Store and Load". 
➢  Jump to: Set the operating status of the oscilloscope to "STOP". Then, 
select the data of the specified time from the event table. Press Jump 
to and the specified data waveforms are displayed in the center of the 
screen. 
➢  Decode: The setting of this menu enables you to quickly view the 
corresponding event tables of four decode modules (Decode1, 
Decode2, Decode3, and Decode4). Press Decode and rotate the 
multifunction knob    to select a decode module, then press down 
the knob to select it. You can also press Decode continuously or 
enable the touch screen to select it. 
 
 
LIN Decoding (Option) 
 
The oscilloscope samples the LIN signal, and judges each data point to be logic "1" 
or logic "0" according to the preset threshold level. The LIN decoding is required to 
specify the LIN signal protocol version. 
 
In the decode setting menu, press Decode1 → Bus Type, then rotate the 
multifunction knob    to select "LIN". Press down the knob    to select it. You can 
also press Bus Type continuously or enable the touch screen to select it. 
 
1.  Enable or disable the bus 
Press Bus Status continuously to enable or disable the decoding function. 
 
2.  Quickly apply LIN trigger settings to LIN decoding 
Press  Copy  Trig  to  copy  the  LIN  trigger  settings  and  apply  them  to  LIN